Cause-and-Effect Matrix.
Also known as · C&E matrix · Cause-effect register
Written, signed, witnessed table tying every input event (fire, nurse-call, medical-gas, access-control, CCTV, BMS) to every gated output (PA, AHU damper, lift, mag-holders, CCTV bookmark, BMS log) with acknowledgement-delay tiers.
- Entity kind
- operational concept
- Relevance
- 95 / 100
- Authority
- 100 / 100
- Aliases
- C&E matrix · Cause-effect register
/ Engineering meaning
What it is and where it sits
Written, signed, witnessed table tying every input event (fire, nurse-call, medical-gas, access-control, CCTV, BMS) to every gated output (PA, AHU damper, lift, mag-holders, CCTV bookmark, BMS log) with acknowledgement-delay tiers.
Tags · concept · fire · operational-contract
Engineering graph
What this connects to (outgoing edges)
Supports
Hospital ELV Stack
Clinical-occupancy ELV coordination — fire-alarm, nurse-call, medical-gas alarm, access-control, IP-CCTV and BMS converging on a cause-and-effect supervisory matrix with NABH pressure-boundary discipline and OT-anaesthesia acknowledgement-delay tiers.
Supports
High-Security ELV Stack
Coordinated perimeter screening (UVSS, ANPR, X-ray, RFID auto-recognition), control-room CCTV, EPABX-LAN backbone, per-load UPS topology, chemical-earthing strategy and hand-off boundaries to convenience features that run in parallel with screening.
Services
Where this maps to services
Semantic similarity
Similar entities in the graph
Similarity 60
Hospital ELV Stack
Clinical-occupancy ELV coordination — fire-alarm, nurse-call, medical-gas alarm, access-control, IP-CCTV and BMS converging on a cause-and-effect supervisory matrix with NABH pressure-boundary discipline and OT-anaesthesia acknowledgement-delay tiers.
Similarity 45
High-Security ELV Stack
Coordinated perimeter screening (UVSS, ANPR, X-ray, RFID auto-recognition), control-room CCTV, EPABX-LAN backbone, per-load UPS topology, chemical-earthing strategy and hand-off boundaries to convenience features that run in parallel with screening.
Similarity 12
IS 2189 — Fire Detection
Indian Standard for the selection, installation and maintenance of automatic fire-detection and alarm systems. Cited line-by-line in every TechnoGuru fire-alarm engineering pack.
Similarity 12
Fire-Alarm ↔ PA Interoperability
Addressable fire-alarm panel ↔ EN 54-16 / IS 14735 PA voice-evac integration. The fire panel triggers zone-specific evacuation announcements with STI ≥ 0.5 intelligibility across the affected zones.
· Engineering entity · operational concept